Independent TMR mixer sizing & multi-brand sourcing · US & Canadaquotes@rmhmixers.comparts@rmhmixers.com
Parts guide

TMR scale systems, load cells & calibration

Weigh bars, load cells, junction boxes and indicators from Digi-Star and Avery Weigh-Tronix: how to tell a percentage error from a fixed error, and what each repair costs.

How a mixer scale works

Three or four load cells or weigh bars sit between the tub and the frame. Each sends a small signal through its cable to a junction box, which sums them and passes one signal to the indicator in the cab or on the mixer. Most North American mixers use Digi-Star (part of Topcon) or Avery Weigh-Tronix indicators; Dinamica Generale and builder-specific systems are common on European machines.

Load cells, weigh bars and indicators together fall in the $800–$4,500 range per repair.
ComponentFails asTypical cost
Load cell / weigh barDrifting zero, one corner reading wrong, water ingress$800–$2,000 each
Junction boxCorroded terminals, moisture, jumpy readings$150–$600
Cables / cordsCut or chewed, intermittent signal$80–$400
Cab indicatorDead display, keypad, lost calibration, no data export$1,200–$4,500

Percentage error vs. fixed error

These two faults look alike on the display and hurt the ration differently.

  • Percentage (span) error: the scale reads, say, 3% light on every load. Big ingredients are off by hundreds of pounds and feed inventory drifts from what the books say. Usually a calibration or a failing cell.
  • Fixed (offset) error: the scale is off by the same 20–50 lbs no matter the load. On a 10,000 lb batch it hardly shows, but on a 40 lb mineral or premix inclusion it can double or halve the dose. Usually a zero problem, a binding tub or a junction box fault.

Field checks before you call

  1. Zero with the tub empty and cleanDoes it hold zero for a minute? Wandering zero points to moisture or a failing cell.
  2. Corner testStand on or press each corner; each should add a similar amount. One dead corner means one cell or its cable.
  3. Known-weight testLoad a weighed bale or a measured quantity of water; compare.
  4. Look for bindingFeed build-up, a rubbing conveyor or a bent stop bolt can carry weight around the cells.

Mail-in repair and loaner indicators

Indicators can usually be bench-repaired. Because nobody can skip morning feeding, ask for a loaner indicator while yours is out; good scale shops ship one the same day. Send a scale repair request with brand, model and the symptom.